97–99%
Salt rejection
≤10 / ≤3 μS/cm
Conductivity
0.25–500 m³/h
Capacity

One engineering platform, two purity levels: single stage RO delivers economical pure water at ≤10 μS/cm for general industry, and double stage RO adds a second membrane pass for ≤3 μS/cm permeate feeding electronics, pharmaceutical and EDI duties.

Discuss Your Requirement
KONCHE single and double stage reverse osmosis skid with membrane housings, high-pressure pump and PLC control cabinetRO MEMBRANESHP PUMPPLC CABINET
KONCHEINDUSTRIAL WATER TREATMENT SYSTEMSMODEL KONCHE RO-S / RO-D · SINGLE & DOUBLE STAGE REVERSE OSMOSISPLC AUTO CONTROLONLINE MONITORINGEDI-READY OPTIONENGINEERED BY KONCHE · 2026
QUICK TECHNICAL ANSWER

What are single and double stage reverse osmosis systems?

KONCHE single stage RO: one-pass membrane separation at 97–99% salt rejection and ≤10 μS/cm permeate. KONCHE double stage RO: two-pass separation polishing permeate to ≤3 μS/cm at ≥75% total recovery, across 0.25–500 m³/h.

How KONCHE scopes an RO project

  • Each proposal re-checks the feed report against the required permeate standard, demand profile and recovery target.
  • Values on this page are reference ranges for the stated conditions; final membrane selection, instruments and guarantees are confirmed after engineering review.
Complete single and double stage reverse osmosis system process diagram
PRODUCT DOCUMENTATION

For boiler make-up, electroplating rinse, food ingredients and chemical processes, single stage RO is often the most economical route to stable pure water. When the conductivity target drops to ≤3 μS/cm or the water feeds EDI, double stage RO adds the second pass the duty requires.

Product documentation

A single stage reverse osmosis (RO) system is a one-pass, pressure-driven membrane train that rejects 97–99% of dissolved salts and supplies industrial pure water with conductivity up to 10 μS/cm. A double stage RO system passes first-stage permeate through a second membrane stage for deeper separation, polishing product water to ≤3 μS/cm at a total recovery of at least 75% in suitable designs, and is a common feed stage ahead of EDI ultrapure trains. Typical KONCHE configurations span 0.25–500 m³/h at operating pressures of 1.0–1.6 MPa for single stage and 1.0–1.5 MPa for double stage, with PLC control and online monitoring; brackish-water duties typically use 0.8–1.5 kWh/m³, protected by multi-media, activated-carbon, softening and 5 μm security filtration matched to the verified feed-water report. Both configurations share one engineering platform, so a single-stage plant can reserve interfaces for a future second-pass or EDI upgrade.

KEY COMPONENTS

01

Pretreatment system

Multi-media filtration, activated carbon and softening remove suspended solids, residual chlorine and hardness to protect the RO membrane.

02

Fine filter

A 5 μm security filter captures particles that may escape pretreatment and provides the final protection before the RO membrane.

03

High-pressure pump

Provides the 1.0–1.6 MPa (single stage) or 1.0–1.5 MPa (double stage) pressure required for membrane separation and is the main energy-consuming component.

04

RO membrane assembly

The core separation unit, with membrane pore size of approximately 0.0001 μm; double-stage plants add a second train sized against the conductivity target.

05

Pure-water tank and post-treatment

Pure water is stored in a hygienic tank; UV disinfection can be added to prevent secondary contamination.

CORE BENEFITS

AdvantageCustomer benefit
Salt rejection 97–99%Genuine branded membrane elements, stable product water and no exaggerated specification.
Right-sized puritySingle stage at ≤10 μS/cm for ordinary duties; double stage at ≤3 μS/cm for electronics, pharmaceutical and EDI feed — typically 30–50% lower investment for single-stage duties.
Water-saving designSingle-stage recovery of 65–85%; double-stage concentrate recycle raises total recovery to at least 75%.
Automatic operationPLC control, online conductivity monitoring, alarm for abnormal water quality and automatic flushing.
UpgradeableSingle-stage plants can reserve interfaces for a second pass or EDI when water-quality requirements increase.

TECHNICAL DATA

ParameterSingle Stage RODouble Stage RO
Model rangeKC-RO-S-0.25 to KC-RO-S-500KC-RO-D-0.25 to KC-RO-D-500
Water treatment capacity0.25–500 m³/h0.25–500 m³/h
Salt rejection rate97–99 %≥99 % total
Product-water conductivity≤10 μS/cm≤3 μS/cm
Recovery65–85 %≥75 % total (first 50–75 %, second 60–80 %)
Operating pressure1.0–1.6 MPa1.0–1.5 MPa
Feed-water temperature5–45 °C5–45 °C
RO membrane4040 / 80404040 / 8040
ControlPLC automatic control + online water-quality monitoring

MODEL RANGE

ModelCapacityTypical application
KC-RO-S-0.25/0.50.25–0.5 m³/hLaboratories, clinics and small production lines
KC-RO-S-1/31–3 m³/hFood and beverage, electroplating and chemicals
KC-RO-S-5/105–10 m³/hBoiler make-up and electronics cleaning
KC-RO-S-20/5020–50 m³/hCentralized supply for large factories
KC-RO-S-100+100+ m³/hIndustrial parks and large bases; customized

Double-stage variants (KC-RO-D) share the same capacity steps. Capacity and configuration of every model can be customized to actual project requirements.

INDUSTRY APPLICATIONS

IndustryWater pointValue
Power boilerBoiler make-upRemoves hardness and salts to reduce scaling and tube failure risk.
Electronics and semiconductorsWafer, component and glass cleaningDouble-stage permeate at ≤3 μS/cm reduces ionic residue and water marks.
PharmaceuticalsPurified-water preparationDouble RO permeate can be used as a purified-water source after required post-treatment.
ElectroplatingBath preparation and rinsingReduces impurities and improves plating consistency.
Food and beverageIngredient and bottle-washing waterSupports hygienic production-water requirements.
Chemical processingReaction, formulation and coolingStable water quality supports process consistency.

SELECTION GUIDE

Selection factorHow to assessRecommendation
CapacityDetermine peak water demandSelect approximately 1.2 times peak demand and add a pure-water tank for buffering.
Feed-water qualityTDS, hardness, iron and manganeseIf TDS is above 1,000 ppm, consider double stage RO; high hardness needs softening.
Product-water targetConductivity requirementSingle stage RO: ≤10 μS/cm; double stage RO: ≤3 μS/cm.
ApplicationBoiler, electroplating, food or drinking waterFood applications can use 304/316L stainless steel; boiler systems may require deaeration.
Membrane brandImported or domesticSelect imported elements for demanding duties or domestic elements for cost control.

REFERENCE PROJECT

Representative KONCHE RO projects (client names anonymized):

20 m³/h double stage RO system delivered for an optoelectronics manufacturer in Huizhou.

IndustryOptoelectronics manufacturing
Capacity20 m³/h
ProcessDouble stage RO

Replaced the plant's aging equipment: permeate conductivity is stable at ≤3 μS/cm, supplying high-quality feed water for the downstream EDI system, with overall line energy consumption reduced by approximately 15%.

MAINTENANCE

ItemCycleMaintenance
Pretreatment filtersMonthlyCheck the 5 μm security-filter differential pressure and replace when blocked.
RO membrane cleaningEvery 3–6 monthsAcid cleaning for carbonate scale and alkaline cleaning for organics and colloids.
RO membrane replacementEvery 2–3 yearsReplace when salt rejection falls by more than 5% or capacity falls by 20% and cleaning is ineffective.
Antiscalant dosingWeeklyCheck the dosing-tank level and adjust dosage to feed-water flow.
High-pressure pumpEvery 3 monthsCheck vibration, noise, seals and lubrication.
Instrument calibrationEvery 3 monthsCalibrate conductivity meter, pressure gauge and flow meter.
Tank cleaningEvery 6 monthsClean raw-water and pure-water tanks to control microbial growth.

FAQ

How do I choose between single and double stage RO?

Choose single stage RO for ordinary industrial cleaning and boiler make-up where conductivity up to 10 μS/cm is acceptable. Choose double stage RO when the target is ≤3 μS/cm, or when the water feeds EDI and electronics or pharmaceutical processes.

Can single stage RO water be used for drinking?

The water quality is better than tap water, but direct drinking also requires post activated carbon and UV disinfection. Konche can provide a complete drinking-water system.

How often should the RO membrane be replaced?

Normally every 2–3 years with proper pretreatment. Poor feed water or incorrect operation can cause fouling earlier.

What feed-water conditions are required?

Reference requirements are turbidity ≤1 NTU, SDI ≤5 and residual chlorine ≤0.1 mg/L. Municipal water may be suitable after confirmation; groundwater normally needs stronger pretreatment.

Does double stage RO save water compared with two single-stage trains?

In suitable designs the second-stage concentrate is recycled to the first-stage feed, raising total recovery to at least 75% and reducing concentrate discharge for the same duty.

WHY KONCHE

01

Nearly 30 years of expertise

Since 1997, Konche has accumulated practical experience across raw-water conditions, treatment processes and industrial project delivery.

02

Professional customization

Each system is designed around the water analysis, industry standard, site condition, capacity and final use.

03

Controlled system quality

Component selection, factory testing, water-quality verification and process control are managed as one complete system.

04

Full-cycle technical service

KONCHE supports proposal alignment, technical documentation, consumables supply, maintenance guidance and remote operational clarification.

PROJECT INQUIRY

Tell us about
your water.

Send your water analysis, target capacity and application. Konche will help select and configure the suitable system.

Get Expert Support