30 m³/h · SINGLE-PASS RO COMPLETED & OPERATING · BOTTLE-WASHING WATER

Philippines 30 m³/h RO System for Bottle-Washing Water

Philippines · Delivered and operating since 2025 · Customer identity withheld

Konche (Shenzhen) Water Treatment Technology Co., Ltd. completed equipment delivery for this project, and the equipment was put into use in 2025. The 30 m³/h single-pass RO installed system treats underground well water for exterior bottle washing at a beverage-production facility. It is a dedicated washing-water duty, not a claim that the treated water becomes part of the beverage.

Location
Philippines; customer and city withheld
Application
Exterior bottle washing at a beverage-production project
Feed water
Underground well water
Installed capacity
30 m³/h single-pass RO permeate
Installed treatment train
Two-vessel pretreatment, cartridge filtration, antiscalant dosing and single-pass RO
Status
Delivered and operating since 2025

What is the best water treatment for well water?

The right treatment depends on the water analysis and the intended use. For this bottle-washing project, the requirement was a stable treated-water stream from an underground well, so the installed system combines media pretreatment, cartridge protection and single-pass reverse osmosis.

Do I really need a reverse osmosis system with well water?

RO is appropriate when dissolved salts or other water-quality limits cannot be controlled by filtration alone. The bottle-washing duty required reduced dissolved solids after pretreatment, while the facility's hygiene program remained responsible for the final cleaning and microbial-control plan.

How does an industrial reverse osmosis system work?

The installed system specifies well-water lift → quartz-sand filtration → activated-carbon filtration → antiscalant dosing → 5 µm cartridge filtration → high-pressure pumping → single-pass RO → product-water storage. It places two stainless-steel pretreatment vessels ahead of the RO stage and includes membrane flushing, a cleaning loop, level interlocks, pressure protection, alarms and monitoring of conductivity, pH, flow and pressure.

Water-quality note: conductivity, pH, recovery and microbial limits were set for the bottle-washing duty and remain part of routine operating control.

What should be tested in well water?

Share the well-water analysis, required treated-water flow, operating hours, bottle-washing method, storage volume, cleaning regime, electrical supply and the plant's target limits for conductivity, hardness and microbiology. These inputs determine the pretreatment, membrane selection, disinfection boundary and acceptance plan.