UNITED STATES · 2 m³/h SINGLE-PASS RO COMPLETED & OPERATING · FORMULATION WATER

United States 2 m³/h Formulation-Water RO System

United States · Delivered and operating since 2025 · Three-vessel pretreatment installed system

Konche (Shenzhen) Water Treatment Technology Co., Ltd. completed equipment delivery for this project, and the equipment was put into use in 2025. The 2 m³/h single-pass RO installed system prepares formulation water for chemical, detergent, household-cleaner, shampoo and personal-care production using municipal tap water as the feed-water basis.

Location
United States; customer and facility withheld
Application
Formulation water for chemical, detergent and personal-care products
Feed-water condition
Municipal tap water; operating settings established from the project water analysis
Installed capacity
2,000 L/h net single-pass RO permeate
Installed treatment train
Three-vessel pretreatment, cartridge filtration, single-pass RO and downstream UV
Status
Delivered and operating since 2025
Three-vessel stainless-steel pretreatment and reverse-osmosis system in a clean workshop
Three-vessel stainless-steel pretreatment and single-pass RO configuration view; not a site-installation photograph.

What is an RO water treatment system?

An RO system uses pressure and a semipermeable membrane to reduce dissolved salts and other small dissolved constituents. For formulation water, it provides a controlled base stream that can then be stored, distributed and managed under the manufacturer's production-quality plan.

How does an industrial reverse osmosis system work?

The installed system specifies municipal feed → SS304 sand filtration → SS304 activated-carbon filtration → SS304 softening → 5 µm cartridge filtration → high-pressure pumping → single-pass RO → downstream UV → tank or point of use. It includes three stainless-steel pretreatment vessels, an SS304 skid and piping, a conductivity meter, pressure gauges, flow meters, float switches and PLC control.

Formulation-water quality requirements

The target depends on the formulation, stability testing, microbial controls and production quality plan. Detergents, household cleaners, shampoos and personal-care products may not share one universal conductivity or microbial specification, so the acceptance limits must be defined product by product.

Capacity note: the installed RO production rating is 2,000 L/h net permeate. Any separate lower-purity outlet must be defined by its own point-of-use requirement.

How to choose an RO system?

Define the municipal-water analysis, each product's formulation-water specification, peak and daily demand, tank and distribution-loop design, sanitization method, microbial control, electrical supply, validation documents and the split between standard and lower-purity outlets.

PROJECT INQUIRY

Define formulation-water requirements.

Share the feed-water analysis, formulation limits, daily and peak demand, storage, loop and sanitization requirements.

Review Project Fit ↗