RUSSIA · WINTERIZED CONTAINERIZED BWRO COMPLETED & OPERATING · TECHNICAL WATER

Russia Containerized Brackish-Water System

Russia · Delivered and operating since 2025 · Technical water and concentrate management

Konche (Shenzhen) Water Treatment Technology Co., Ltd. completed equipment delivery for this Russian project, and the equipment was put into use in 2025. The winterized installed system produces technical water from dedicated-well feed while recovering part of the primary RO concentrate and conditioning the remaining concentrate for reinjection.

Location
Russia; customer and site withheld
Application
Dedicated-well feed to technical water, with concentrate conditioning and reinjection
Installed format
Winterized ISO-container treatment package
Configured flow
18.75 m³/h nominal feed and at least 16 m³/h product water
Installed treatment train
Primary RO, concentrate-recovery RO, product conditioning, concentrate deoxygenation and reinjection
Status
Delivered and operating since 2025

Containerized brackish-water treatment system

It is a complete treatment package designed inside one or more insulated containers so that piping, controls, membranes and chemical systems can be shipped as integrated modules. This Russian installed system requires winterization for low ambient temperatures and a closed approach to both product water and concentrate handling.

How does a containerized desalination plant work?

The installed treatment train uses feed protection and buffering → selective sulfate and metal control → media and oil-polishing filtration → cartridge filtration → primary RO → concentrate-recovery RO → product conditioning and storage. The concentrate-management section then applies physical deoxygenation, chemical oxygen scavenging, closed buffering and reinjection pumping.

What is concentrate management for industrial RO?

The installed system sends part of the primary RO concentrate to a recovery RO stage to increase product-water output. The remaining concentrate is conditioned for reinjection, with online dissolved-oxygen monitoring, deoxygenation and a controlled high-pressure reinjection duty.

Materials and controls: high-pressure brine-side materials must match the actual water chemistry. The installed system includes local HMI functions, redundant control and power provisions, online product-water pH monitoring and concentrate dissolved-oxygen monitoring.

What are the typical specifications for reverse osmosis systems?

Provide the full and seasonal water analysis, dissolved gases, suspended solids, oil and organics, product-water specification, required recovery, concentrate-disposal or reinjection route, ambient specified temperatures, hazardous-area requirements, utility limits, materials philosophy, redundancy and FAT/SAT requirements.

PROJECT INQUIRY

Define a containerized BWRO package.

Share the complete water analysis, product-water target, recovery duty, concentrate route, ambient range and redundancy requirements.

Review Project Fit ↗